This appliance is supplied with a
mains cable and a plug.
Always use a correctly installed
shockproof socket.
Make sure that there is an access to
the mains plug after the installation.
Do not pull the mains cable to
disconnect the appliance. Always pull
the mains plug.
There is a risk of fire when the
appliance is in connection with an
extension cable, an adapter or a
multiple connection. Make sure that
the ground connection agrees with
the standards and regulations.
Do not let the power cable to heat up
to a temperature higher than 90° C.
Make sure that you connect
the blue neutral cable to the
terminal with a letter "N" on
it. Connect the brown (or
black) phase cable to the
terminal which has a letter
"L". Keep the phase cable
connected at all times.
body
220-240V
ignition box
to burner spark plugs
knob
ignition
switches
E
N
L
DANGER
220-240 volts AC
Disconnect from
supply before
removing panel
To prevent contact between
the cable and the appliance
below the hob use the
clamps which are on the side
of the cabinet.
4.6 Connection cable
To replace the connection cable use only
the special cable or its equivalent. The
cable type is: H05SS-FT180.
Make sure that the cable section is
applicable to the voltage and the
working temperature. The yellow / green
earth wire must be approximately 2 cm
longer than the brown (or black) phase
wire.
4.7
Assembly
1.
2.
3.
B
min. 650 mm
830
mm
+2
0
C
40 mm
480
mm
+2
0
A
Minimum distances
Dimension mm
A 121
B 113
C 94
Distances shown to
adjacent surfaces are for
the distances to
combustible surfaces. If
the surfaces is not
combustible the
measurements can be
smaller that shown.