8. INSTALLATION
WARNING!
Refer to Safety chapters.
8.1 Before the installation
Before you install the hob, write down
the information bellow from the rating
plate. The rating plate is on the bottom
of the hob.
Model .......................................
PNC .........................................
Serial number ...........................
8.2 Gas Connection
WARNING!
The following instructions
about installation,
connection and
maintenance must be
carried out by qualified
personnel in compliance
with standards and local
regulations in force.
It is necessary that the connection to the
gas mains are carried out by means of an
AGB tap. Choose fixed connections or
use a flexible pipe in AGB (stainless
steel) in compliance with the regulation
in force (NBN D 51.003). If you use
flexible metallic pipes, be careful they do
not come in touch with mobile parts or
they are not squeezed. Also be careful
when the hob is put together with an
oven.
Make sure that the gas
supply pressure of the
appliance obeys the
recommended values. The
adjustable connection is
fixed to the comprehensive
ramp by means of a
threaded nut G 1/2". All the
components shown in the
figure have already been
assembled in the factory.
The appliance, before
leaving the factory, has been
tested in order to give you
the best results.
A) End of shaft with nut
B) Washer
C) Elbow (if needed)
Liquid gas
Use the rubber pipe holder for liquid
gas. Always engage the gasket. Then
continue with the gas connection.
The flexible pipe is prepared for apply
when:
• it can not get hot more than room
temperature, higher than 30°C;
• it is no longer than 1500 mm;
• it shows no throttles;
• it is not subject to traction or torsion;
• it does not get in touch with cutting
edges or corners;
• it can be easily examined in order to
make sure its condition.
The control of preservation of the flexible
pipe consists in checking that:
• it does not show cracks, cuts, marks of
burnings on the two ends and on its
full length;
• the material is not hardened, but
shows its correct elasticity;
• the fastening clamps are not rusted;
• expired term is not due.
If one or more defects are visible, do not
repair the pipe, but replace it.
WARNING!
When installation is
complete, make sure that
the seal of each pipe fitting
is correct. Use a soapy
solution, not a flame!
8.3 Electrical connection
• Make sure that the rated voltage and
type of power on the rating plate
www.aeg.com