For the Fitter
Fig. 2 Fixing the capillary-tube thermostat
Fig. 3 Push on adjuster knob
2.3 Installation and Electrical Connection
●
The installation and Electrical Connection may
only be carried out by a competent electrician.
●
Turn off all electricity supplies to the heater.
To do this, interrupt the electricity supply to
both the charge and the discharge circuits.
Caution: Even if the main circuit breakers
are switched off, some terminals
carrying on-peak current,
especially terminals A1/Z1 and
A2/Z2 can still be live.
●
Also read the Instruction Leaflet supplied with
the storage heater.
●
Unscrew and remove the top screw from the
left-hand side panel.
●
Remove the right-hand side panel and cover
panel of the storage heater. Break out the
knock-outs in the side panel.
●
Carefully remove the plastic fascia plate from
the inside of the heater front panel using a
screwdriver to gently push out the holding tabs
(Fig. 1).
Attention: The angle of the screwdriver should
be set as close as possible to the
inside of the front panel (oblique
angle prevents breakage of the fascia
plate and/or chipping of the paint-
work).
●
Fix the capillary-tube thermostat to the fixing
plate through the opening in the front panel
using the M4x6 fixing screws supplied (Fig. 2).
●
Push the adjuster knob on to the spindle of the
capillary thermostat (Fig. 3).
Make sure that the wires are not touching
any hot surfaces, that they are neither
damaged nor squeezed when replacing the
side panel and that no internal wiring is
touchable from the outside through the
air-slits.