9.2 Bypass diameters
BURNER Ø BYPASS 1/100 mm
Rapid 56
Semi-rapid 42
Auxiliary 34
9.3 Other technical data
TOTAL POWER: Gas original: G20 (2H) 20 mbar = 8,9 kW
Electric supply: 220-240 V ~ 50/60 Hz
3 core flexible cable with non rewireable plug fitted with a 3 amp
cartridge fuse
Appliance category: I2H
Gas connection: R 1/2"
Appliance class: 3
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER kW MINIMUM POWER
kW
INJECTOR MARK
1/100 mm
Rapid 2,9 1,2 120B
Semi-rapid 2,0 0,75 102
Auxiliary 1,0 0,5 73F
10. ENERGY EFFICIENCY
10.1 Product information according to EU 66/2014
Model identification HG755820UM
Type of hob Built-in hob
Number of gas burners 5
Energy efficiency per gas burner
(EE gas burner)
Centre middle - Rapid 59.4%
Left rear - Semi-rapid 63.2%
Right rear - Semi-rapid 60.0%
Left front - Auxiliary not applicable
Right front - Auxiliary not applicable
www.aeg.com16