9. TECHNICAL INFORMATION
9.1 Hob dimensions
Width 590 mm
Depth 520 mm
9.2 Bypass diameters
BURNER Ø BYPASS 1/100 mm
Rapid 42
Semi-rapid 32
Auxiliary 28
9.3 Other technical data
TOTAL POWER:
Gas original: G20 (2H) 20 mbar = 7,7 kW
Gas replacement: G30 (3+) 28-30 mbar = 545 g/h
G31 (3+) 37 mbar = 536 g/h
Electric supply: 220-240 V ~ 50/60 Hz
3 core flexible cable with non rewireable plug fitted with a 3 amp
cartridge fuse
Appliance category: II2H3+
Gas connection: R 1/2"
Appliance class: 3
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER kW MINIMUM POWER
kW
INJECTOR MARK
1/100 mm
Rapid 2,9 0,75 119
Semi-rapid 1,9 0,45 96
Auxiliary 1,0 0,33 70