
Kitchen unit with oven
The electrical connection of the hob and
the oven must be installed separately for
safety reasons and to let easy remove
oven from the unit.
9. TECHNICAL INFORMATION
9.1 Hob dimensions
Width 590 mm
Depth 520 mm
9.2 Bypass diameters
BURNER Ø BYPASS 1/100 mm
Rapid 42
Semi-rapid 32
Auxiliary 28
9.3 Other technical data
TOTAL POWER:
Gas original: G20 (2H) 20 mbar = 7,7 kW
Gas replacement: G30 (3+) 28-30 mbar = 545 g/h
G31 (3+) 37 mbar = 536 g/h
Electric supply: 220-240 V ~ 50/60 Hz
3 core flexible cable with non rewireable plug fitted with a 3 amp
cartridge fuse
Appliance category: II2H3+
Gas connection: R 1/2"
Appliance class: 3
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER kW MINIMUM POWER
kW
INJECTOR MARK
1/100 mm
Rapid 2,9 0,75 119
Semi-rapid 1,9 0,45 96
Auxiliary 1,0 0,33 70
www.aeg.com16
Comentarios a estos manuales