9 9
F
GAS ADJUSTMENT
C
GB
A B
Unscrew the adjusting screw in order to increase the flow or screw
it to decrease the flow.
The right adjustment is obtained when the flame has a length of
about 3 or 4 mm.
For butane/propane gas, the adjusting screw must be tight screwed.
Make sure that the flame does not go out passing quickly from
the max. flow to the minimum flow and viceversa .
Assemble the knob again.
MINIMUM FLOW ADJUSTMENT FOR OVEN THERMOSTAT
In order to adjust the minimum, act as follows: switch the burner
on turning the knob to the maximum position.
Remove the knob and unscrew of some turns the by-pass screw
(fig. H).
Assemble the knob and let the oven warm up for 15 minutes; after
that turn the knob to the minimum position.
Fig. 11
Fig. 12
Z
If the appliance is foreseen to operate with a type of gas different
from the suitable supply gas, proceed as follows: change the
injectors, adjust the minimum flow of the burners, change the
push-on connector.
In order to change the work-top injectors, it is necessary to act as
follows: remove the grids, remove burners and flame-spreaders
(see fig.A), change the injector (see fig.B) and replace it with
another one suitable for the new type of gas (see table D). Re-
assemble everything in the opposite direction, paying attention to
place the flame-spreader in the right way on the burner.
To change the oven injector, it is necessary to act as follows: open
the oven door, remove the lower side of the oven (see fig.C),
unscrew screw C and disassemble the oven burner (see fig.D).
Change the injector (see fig.E) and replace it with another one
suitable for the new gas type (see table D).
Re-assemble everything in the opposite direction, paying attention
to place the burner in the right way on its rear slot.
To change the grill injector, it is necessary to act as follows: open
the oven door, unscrew screw C and disassemble the grill burner
(see fig.F). Change the injector (see fig.G) and replace it with
another one suitable for the new gas type (see table D).
Re-assemble everything in the opposite direction, paying attention
to place the burner in the right way on its rear slot.
MINIMUM FLOW ADJUSTMENT FOR WORK-TOP TAPS
In order to adjust the minimum, act as follows: switch the burner
on, and turn the knob towards the minimum flow position .
Remove the knob from the tap, introduce a little screwdriver in the
tap rod (fig. 11).
Attention: in taps with security valve, the minimum adjusting screw
“Z” is placed outside the rod tap (fig. 12).
FIG.E
FIG.C
FIG.D
FIG.G
F
¦
"
FIG.F
C
TAB. D GENERAL INJECTORS TABLE
Kind of gas mbar Nozzle Burners Power Watt Consum.
N. Position-type max. min. max.
1.15 Rapide 3000 750 286 l/h
NATURAL 20 0.97 Semi rapide 1750 480 167 l/h
0.72 Auxiliary 1000 330 95 l/h
1.28 Triple crown 3300 1300 315 l/h
1.45 UltraRapide 3600 1500 343 l/h
1.20 Fish 2900 1500 277 l/h
1.50 Oven 4300 389 l/h
1.45 Grill 3800 344 l/h
G.P.L. 30 0.85 Rapide 3000 750 219 g/h
BUTANE 28 0.65 Semi rapide 1750 480 128 g/h
PROPANE 37 0.50 Auxiliary 1000 330 73 g/h
0.93 Triple crown 3300 1300 241 g/h
0.96 UltraRapide 3600 1500 262 g/h
0.85 Fish 2900 1500 211 g/h
1.00 Oven 4300 313 g/h
0.95 Grill 2800 277 g/h
NATURAL 20 1.25 Grill 2800 253 l/h
G.P.L. 30 0.75 Grill 2800 204 g/h
BUTANE 28
PROPANE 37
with separated thermostat