Dimension mm
D 400
E 150
F less than 400
13.3 Levelling of the appliance
Use small feet on the bottom of
appliance to set the appliance top
surface level with other surfaces.
13.4 Other technical data
WARNING!
These instructions are only
valid in the countries whose
symbols appear on this
booklet's cover.
Gas category: I2H
Gas supply: G20 (2H) 20 mbar
Voltage: 220-240 V
Frequency: 50 Hz
13.5 Gas burners
BURNER NORMAL POWER
kW
Natural Gas
INJECTOR MARK 1/100
mm
Btu/h
Auxiliary 1 70 3412
Semi-rapid 1.9 96 6483
Rapid 3 119 10236
13.6 Gas Connection
Use a flexible pipe in compliance with
the regulation in force. Make sure they
do not come in touch with mobile parts
and are not squeezed.
WARNING!
Only a qualified and
competent person can do
the gas installation.
Before you connect te gas,
disconnect the appliance
from the electricity supply or
switch off the fuse in the fuse
box. Close the primary valve
of the gas supply.
Supply piping should not be
less than R3/8. Connection is
made to the Rc 1/2 (1/2
“ B.S.P.) female threaded.
The entry pipe is located just
below the hob level on the
rear left hand side of the
appliance.
The gas supply ramp is on
the rear side of the
appliance.