BURNER NORMAL POWER kW MINIMUM POWER
kW
INJECTOR MARK
1/100 mm
Rapid 3,0 0,75 119
Semi-rapid 2,0 0,45 96
Auxiliary 1,0 0,33 70
9.5 Gas burners for LPG G30/G31 28-30/37 mbar
BURNER NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK 1/100
mm
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Triple Crown 4,0 1,4 98 291 286
Rapid 2,8 0,75 86 204 200
Semi-rapid 2,0 0,45 71 145 143
Auxiliary 1,0 0,33 50 73 71
10. ENERGY EFFICIENCY
10.1 Product information according to EU 66/2014
Model identification HG75NM5420
Type of hob Built-in hob
Number of gas burners 5
Energy efficiency per gas burner
(EE gas burner)
Left rear - Semi-rapid 53.0%
Right rear - Rapid 54.7%
Centre Middle - Triple Crown 52.1%
Left front - Semi-rapid 53.0%
Right front - Auxiliary not applicable
Energy efficiency for the gas hob
(EE gas hob)
53.1%
EN 30-2-1: Domestic cooking appliances burning gas - Part 2-1 : Rational use of
energy - General
10.2 Energy saving
• Before use, make sure that the burners and pan supports are assembled correctly.
• Use cookware with diameters applicable to the size of burners.
• Center the pot on the burner.
• When you heat up water, use only the amount you need.
• If it is possible, always put the lids on the cookware.
www.aeg.com