Replacement of the connection cable
To replace the connection cable use only H05V2V2-F T90 or equivalent type. Make sure that
the cable section is applicable to the voltage and the working temperature. The yellow/
green earth wire must be approximately 2 cm longer than the brown (or black) phase wire.
Building In
min. 55 mm
min. 650 mm
560 mm
min. 450 mm
30 mm
480 mm
min. 600 mm
A
A
B
A) supplied seal
B) supplied brackets
Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must be easy to remove and let an easy access in case a
technical assistance intervention is necessary.
min 20 mm
(max 150 mm)
30 mm
60 mm
a
b
a) Removable panel
b) Space for connections
Installation