9.3 Other technical data
TOTAL POWER:
Gas original: G20 (2H) 20 mbar = 11 kW
Gas replacement: G30 (3+) 28-30 mbar = 800 g/h
G31 (3+) 37 mbar = 786 g/h
Electric supply: 230 V ~ 50 Hz
3 core flexible cable with non rewireable plug fitted with a 3 amp
cartridge fuse
Appliance category: II2H3+
Gas connection: R 1/2"
Appliance class: 3
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER kW MINIMUM POWER
kW
INJECTOR MARK
1/100 mm
Triple Crown 4,0 1,4 146
Semi-rapid 2,0 0,45 96
Auxiliary 1,0 0,33 70
9.5 Gas burners for LPG G30/G31 28-30/37 mbar
BURNER NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK 1/100
mm
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Triple Crown 4,0 1,4 98 291 286
Semi-rapid 2,0 0,45 71 145 143
Auxiliary 1,0 0,33 50 73 71
10. ENVIRONMENTAL CONCERNS
Recycle the materials with the symbol .
Put the packaging in applicable
containers to recycle it. Help protect the
environment and human health and to
recycle waste of electrical and electronic
appliances. Do not dispose appliances
marked with the symbol with the
household waste. Return the product to
your local recycling facility or contact
your municipal office.
*