AEG 6531DG-M Manual de usuario Pagina 5

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 10
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 4
5
Description of the product
Burner
Control knob
16
Cable type 0,75 mm² HO5 V2V2-F
The Dropinett must be connected via
an external switch with a contact
gap of min. 3 mm (the main switch
may be used)
Wiring
Type of gas
Adjusted to nateral gas: G20 - 20 mbar
Category and pressures
ZA: II
2ELL3B/P
- 20 - 50 mbar
Convertible to
Bottled gas - G30 - 50 mbar
Max. nominal load Q na H
S
:
Medium sized burner = 1,9 kW x 1
Large sized burner = 3,0 kW x 1
Total= 4,9 kW
FSD
The unit features fully-secured gas
taps (thermo-fuse).
H
S
= Top calorific value
Q = Nominal load
ID. CE-048BO-0037
Ignition transformer= 50 HZ - 0,6 VA
Radio-noise reduction
This unit observes the current EEC-
directive on radio noise reduction.
This gas appliance is -approved and
marked in accordance with the gas
appliance Directive (90/396/CEE), the
low voltage directive (73/23/CEE) and
the EMC directive (89/336/CEE incl.
the agreed directive changes.
Technical data
HO5V2V2-F
Yellow/Green: 61 mm +/- 3 mm
Blue and brown: 51 mm +/- 3 mm
N L1
240 V
1N + PE
Vista de pagina 4
1 2 3 4 5 6 7 8 9 10

Comentarios a estos manuales

Sin comentarios