Aeg COMPACT READER ARE I2 Manual de usuario Pagina 25

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 33
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 24
Manual
Page 25 / 33- Revision 01
ARE I2 / RS 232 – Installation Guide
AEG
Identifikationssysteme GmbH
Söflinger Straße 100
D-89077 Ulm
Tel. ++49(0)731-933-1340/1877
Fax ++49(0)731-933-1855
Wait for the answer
Analyse the received answer: 3 characters plus <CR>.
<ACK> <CR> Writing process was successful
<NAK> <CR> Writing process was not successful.
<NOT> <CR> The response of the transponder was not readable.
The result of the writing process may also seen at the LED’s.
LED L2 lit, if there was a successful write
LED L3 lit, if there was no successful write.
Example
WD <SP> 20 <SP> < 0 1 2 7 A C D F > <CR> Write to block 20
Allowed Values (block numbers of the transponder IC):
ALGO 9 (1kBit Memory) 3 .... 31
ALGO 6 (2kBit Memory) 16 ... 63
Vista de pagina 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 31 32 33

Comentarios a estos manuales

Sin comentarios