9. TECHNICAL DATA
9.1 Hob dimensions
Width 880 mm
Depth 510 mm
9.2 Bypass diameters
BURNER Ø BYPASS 1/100 mm
Triple Crown 57
Semi-rapid 35
Auxiliary 28
9.3 Other technical data
TOTAL POWER:
Gas original: G20 (2H) 20 mbar 10,5 kW
Gas replace-
ment:
G30 (3+) 28-30 mbar 763 g/h
G31 (3+) 37 mbar 750 g/h
Electric supply: 220-240 V ~ 50/60 Hz
Appliance cate-
gory:
II2H3+
Gas connection: G 1/2"
Appliance class: 3
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER kW MINIMUM POWER
kW
INJECTOR MARK
Triple Crown 3,8 1,4 146
Semi-rapid 1,9 0,6 96x
Auxiliary 1,0 0,33 70
9.5 Gas burners for LPG G30/G31 28-30/37 mbar
BURNER NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Triple Crown 3,8 1,4 98 276 271
www.aeg.com18